          Civil construction insulation systems and external decorative fire Interim Provisions (public through word [2009] No. 46)
           

          Ministry of public security 
          Housing and Urban-Rural Development 
          Public through word [2009] No. 46 
          On the issuance of "civil external facade insulation systems and fire Interim Provisions" 
          Provinces, autonomous regions and municipalities Public Security Bureau, Bureau of Housing and Urban Construction Department, Construction, Jiangsu, Shandong Provincial Construction Authority, the Public Security Bureau of Xinjiang Production and Construction Corps Construction Bureau: 
          To effectively prevent the building insulation system fire accident, the Ministry of Housing and Urban jointly developed a "civil construction facade insulation systems and fire Interim Provisions", issued to you now. Please combined with actual work, conscientiously implemented. After the revision of the relevant standards, according to relevant regulations issued by the implementation of standards. 
                                                                                                                 People's Republic of China Ministry of Public Security 
                                                                                            People's Republic of China Ministry of Housing and Urban-Rural Development 
                                                                                                                   September 25, 2009 
          [Editorial] source of the CPC Central Committee CCTV fire caused by the State Council attach great importance to Premier Wen Jiabao, necessity and contingency fires cause heavy losses lesson, do not continue past practice for it, on September 25 by the Ministry of Public Security and live built jointly issued public through word [2009] No. 46, gave me the building industry design and manufacturing enterprises must conscientiously implement the "civil insulation systems and external decorative fire Interim Provisions" document, article core is lifted only consider building regardless of external insulation wall decoration not fire practice it gone! Bottom line: If there is no people's lives and property safety guarantee, but also talk about what is the value or distinction. 

          Civil construction insulation systems and external decorative fire Interim Provisions 
          Chapter I General Provisions 
            The first article of the Interim Provisions applicable to civil construction insulation systems and external decorative fire design, construction and use. 
               Combustion performance should be the second civil construction insulation materials for the A-level, and should not be less than the B2 level. 
               Article civil construction insulation systems and external decorative fire protection design, construction and use, in addition to the implementation of the Interim Provisions, shall comply with the relevant provisions of current national standards. 
          Chapter Wall body 
              Article non curtain-style buildings should meet the following requirements: 
              (A) residential buildings should meet the following requirements: 
              1, a height greater than or equal to 100m building, the combustion performance of insulation materials should be A grade. 
              2, height greater than or equal 60m less than 100m building, the combustion performance of insulation materials should not be less than the B2 level. When using the B2 grade insulation material, each level of fire buffer zone should be set. 
              3, the height of not less than 24m less than 60m building, the combustion performance of insulation materials should not be less than the B2 level. When using insulation material class B2, each two-level fire buffer zone should be set. 
              4, building height of less than 24m, the combustion performance of insulation materials should not be less than the B2 level. Wherein, when using insulation material class B2, every three levels should be set fire buffer zone. 
             (B) Other civil construction shall meet the following requirements: 
              1, a height greater than or equal 50m building, combustion performance of insulation materials should be A grade. 
              2, not less than 24m height less than 50m building, combustion performance of insulation materials should be Class A or B1 level. Wherein, when using the B1 grade insulation material, each two-level fire buffer zone should be set. 
              3, building height of less than 24m, the combustion performance of insulation materials should not be less than the B2 level. Wherein, when using insulation material class B2, each level of fire buffer zone should be set. 
              (C) thermal insulation system shall be non-combustible material for protection layer. The protective layer of insulation material should be completely covered. First floor of the protective layer thickness of not less than 6mm, the other layers of not less than 3mm. 
              (Iv) The exterior insulation system building, the fire resistance of the primary wall should be consistent with the relevant provisions of the existing fire code. 
              Article curtain-style buildings should meet the following requirements: 
              When (a) building height greater than or equal 24m, the combustion performance of insulation materials should be A grade. 
              (B) In the building height of less than 24m, the combustion performance of insulation materials should be Class A or B1 level. Among them, 
          When using B1 grade insulation material, each level of fire buffer zone should be set. 
              (C) The insulation material should be used as the protective layer of non-combustible material. The protective layer of insulation material should be completely covered. Protective layer thickness of not less than 3mm. 
              (Iv) the use of non-transparent curtain wall structure of the building metal, stone, etc., should be set up primary wall, fire resistance should comply with fire safety regulations relevant provisions of the exterior wall fire resistance; glass-curtain wall windows, sills wall, skirt fire resistance and fire wall structure should comply with fire safety regulations relevant provisions of the building walls. 
              (E) The primary wall cavity and internal building walls and base wall, the wall between the windows, the space between the wall and the skirt wall sills, fire blocking material should be closed at each floor office. 
          In accordance with the provisions of Article VI of the need to set fire buffer zone should be set a width of not less than 300mm of A-grade insulation material along the floor position. Fire Barrier whole area of ​​the wall should be pasted. 
          Article exterior wall decorative layer, in addition to the use of paint, shall be non-combustible material. When a building wall with combustible insulation materials should not be used after the fire shedding tiles and other materials. 
          Chapter roof 
              Article VIII does not burn body building to the roof of the grassroots use refractory limit not less than 1.00h, the roof insulation materials not lower than B2 level; other cases, the combustion performance of insulation materials should not be lower than the B1 level. 
              Article IX junction of the roof and exterior walls, roof insulation layer around the opening portion, a width of not less than 500mm should be used in setting the level of A-grade insulation material Fire Barrier. 
              Article X roofing membranes or combustible insulation should be covered with noncombustible material. 
          Chapter IV metal sandwich plates 
              Article XI temporary residential buildings for metal sandwich plates, its core should be fireproof insulation materials. 
            
          Fire safety requirements for construction and use of Chapter V 
              Article XII of construction building insulation system should meet the following requirements: 
              After (a) insulation materials approach, away from fire sources. When open storage should be completely covered with noncombustible material. 
              (B) the need to take structural measures of fire insulation materials, the construction firebreak should be synchronized with the construction of thermal insulation materials. 
              (C) combustible construction flame retardant insulation materials should partition segments, each segment should maintain adequate fire prevention space, and should do the fixed side edge smear protective layer of insulation material. No smear outer protective layer of insulation material height should not exceed 3 layers. 
              (D) a supporting member and an air conditioner and other facilities of the curtain wall of the support member, the welding and other operations should be carried out before laying insulation material. , Should be laid fire blanket protection measures do need to be laid in the insulation material in and around the bottom of the welding site. 
              (E) shall not be melt, thermal bonding construction method waterproof material directly on flammable insulation materials. 
              (Vi) construction near the flammable insulation material should be taken with a reliable fire protection measures temperature and lighting equipment. 
              (7) when the polyurethane foam insulation materials on-site operations, should avoid high temperature environment. Construction technology, tools and clothing, anti-static measures should be taken. 
              (Viii) the construction site should be set up indoor and outdoor temporary fire hydrant system, and to meet the construction site fire fighting fire service requirements. 
              (Ix) external insulation construction work station should be equipped with adequate fire fighting equipment. 
          Daily use of Article XIII building insulation system should meet the following requirements: 
              (A) the exterior walls and roof with attached adjacent shaft, groove, platforms, etc., should not be stacked combustibles. 
              (Ii) fire, heat and other fire hazards and facades, roofs should be kept a safe distance, and should enhance the fire and heat management. 
              (C) should not be carried out construction work welding and drilling on the use of external walls and roof insulation materials. Really necessary construction work should take credible measures for fire protection, and shall, after construction is completed in a timely manner the exposed insulation materials protective treatment. 
              (D) Electrical wiring should not pass through combustible insulation materials. When do need to pass through the fire protection measures should be taken through tubes.

           

           